• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sat, 04.05.24

Search results


December 2015
Yuval Konstantino MD, Tali Shafat BSc, Victor Novack MD PhD, Lena Novack PhD and Guy Amit MD MPH
 

Background: Implantable cardioverter defibrillators (ICDs) reduce mortality in patients implanted for primary and secondary prevention of sudden cardiac death. Data on the incidence of appropriate ICD therapies in primary vs. secondary prevention are limited. 


Objectives: To compare ICD therapies and mortality in primary vs. secondary prevention of sudden cardiac death. 


Methods: We conducted a retrospective analysis of 581 consecutive patients receiving an ICD for primary (66%) or secondary (34%) prevention indications. 


Results: During long-term follow-up, 29% of patients implanted for secondary prevention received appropriate ICD therapy vs. 18% implanted for primary prevention. However, the overall 7 year mortality rate was not significantly different between the two groups (26.9%, P = 0.292). Multivariate analysis showed that patients implanted for primary prevention had a significantly lower risk of appropriate ICD therapy even after adjustment for age, left ventricular ejection fraction < 0.35 and chronic renal failure (HR 1.63, 95%CI 1.10–2.41, P = 0.015).


Conclusions: Patients implanted for secondary prevention were more likely to receive appropriate ICD therapy, with a significantly shorter time period from ICD implant to the first therapy. However, all-cause mortality was comparable between primary and secondary prevention groups. 


 

 
January 2009
H. Gilutz, L. Novack, P. Shvartzman, J. Zelingher, D.Y. Bonneh, Y. Henkin, M. Maislos, R. Peleg, Z. Liss, G. Rabinowitz, D. Vardy, D. Zahger, R. Ilia, N. Leibermann and A. Porath

Background: Dyslipidemia remains underdiagnosed and undertreated in patients with coronary artery disease. The Computer-based Clinical Decision Support System provides an opportunity to close these gaps.

Objectives: To study the impact of computerized intervention on secondary prevention of CAD[1].

Methods: The CDSS[2] was programmed to automatically detect patients with CAD and to evaluate the availability of an updated lipoprotein profile and treatment with lipid-lowering drugs. The program produced automatic computer-generated monitoring and treatment recommendations. Adjusted primary clinics were randomly assigned to intervention (n=56) or standard care arms (n=56). Reminders were mailed to the primary medical teams in the intervention arm every 4 months updating them with current lipid levels and recommendations for further treatment. Compliance and lipid levels were monitored. The study group comprised all patients with CAD who were alive at least 3 months after hospitalization.

Results: Follow-up was available for 7448 patients with CAD (median 19.8 months, range 6–36 months). Overall, 51.7% of patients were adequately screened, and 55.7% of patients were compliant with treatment recommended to lower lipid level. A significant decrease in low density lipoprotein levels was observed in both arms, but was more pronounced in the intervention arm: 121.9 ± 34.2 vs. 124.3 ± 34.6 mg/dl (P < 0.02). A significantly lower rate of cardiac rehospitalizations was documented in patients who were adequately treated with lipid-lowering drugs, 37% vs. 40.9% (P < 0.001).

Conclusions: This initial assessment of our data represent a real-world snapshot where physicians and CAD patients often do not adhere to clinical guidelines, presenting a major obstacle to implementing effective secondary prevention. Our automatic computerized reminders system substantially facilitates adherence to guidelines and supports wide-range implementation.






[1] CAD = coronary artery disease



[2] CDSS = clinical decision support system


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel